Unused 120 man Accommodation Module/Living Quarters. Constructed by Consafe. Construction Completed 2012. 5 1/2 levels, Temporary Refuge, H60/A60, Blast Rated. 56 of 2 man Cabins (no bunk beds) 4 of Single Cabins. Fitted with 22m Helideck. Complete with 2 x Lifeboats and Davits. Designed and built for North Sea. 35m Wide x 15.7m Deep x 22.5m High + 4m for Helideck. 1300 Tonne. Quayside UK. Available Immediately.
TEMPORARY REFUGE
LQ boundary is the Temporary Refuge (TR)
Endurance Period of one (1) hour
BLAST AND FIRE RATING
Blast rated on all faces
Combination of H60 and A60 external
Internal fire rating as per SOLAS
HAZARDOUS AREA CERTIFICATION
(Living Quarters is in a safe area)
External equipment certified for a zone 2 hazardous area
Internal equipment certified for safe area with exception of:
Equipment in air locks
Fire dampers
Gas detectors
Internal Escape lighting
SMOKE AND GAS INGRESS
Constructed to meet air leakage criteria of 0.2 AC/hr @50 Pa
Smoke and gas tight fire dampers on TR perimeter
Fire dampers positioned to facilitate regular testing
FIRE AND GAS DETECTION
F&G detection located at air intakes, roof areas, airlocks, UPS / TER rooms, TEMPSC embarkation areas
Addressable Smoke Detection in Living Quarters
ESCAPE ROUTES
Minimum dimensions/maximum lengths specified
Provision for stretcher access
From incident to Medical Suite / Muster Area; and then subsequently
To the helideck / TEMPSC
Mustering in the LQ
Escape from an internal LQ inscident
Evacuation of Platform (Helicopter or TEMPSC)
NEW ALUMINUM HELIDECK COMPLYING WITH CAP 437 (6th Edition)
NEW HVAC SYSTEM
NEW POTABLE WATER SYSTEM
WELFARE
LAYOUT CONSIDERATIONS
Two man cabins: Single beds, 6 lockers per room, 1 toilet shower cubicle / cabin
Improved leisure facilities: Gymnasium, Sauna, Quiet Room, Recreation Room, Coffee Hub
Linen / Janitor stores at all levels
Dedicated drying space in locker area
Improved working spaces offices, galley, laundry, locker
INTERNAL ENVIRONMENT
Noise levels specified
Illumination levels specified (switched where required)
Individual room temperature control
Steam humidification to ensure minimum humidity achieved
No smoking in Living Quarters
Safety in Design
- Lay-out of heliadmin
- Galley landing / material handling
- External hosereels
- Access to plant from stairs (extract skids)
- Lift for catering staff (material handling)
- Sliding doors (pneumatic assist) on main access doors
STRUCTURE
120 POB (56 off two man cabins, 4 off single man), TEMPSC Provision, Helideck, 1300 Tonnes
LEVEL 1
Galley Mess facilities for sitting of 48 persons
Laundry facilities
Locker Change Room Facilities (249 lockers)
LEVEL 2
Office Suite
Emergency Command and Control (ECC)
Recreation Spaces
LEVEL 3 / 4
Cabins
LEVEL 5
Cabins, UPS / TER, Medic Suite, Helilounge
LEVEL 6
Plant Areas
PIPING/SAFETY
PIPING SYSTEMS
Potable Water Systems
Seawater
Black & Gray Drains (Combined)
Firewater
Helideck DIFFS
Hosereels (typically 3 / floor)
No Sprinklers
POTABLE WATER MAKER INTEGRAL IN LQ
Header tank in LQ
UV Sterilisation
Calorifier ( 2 off 60% vessels)
100% DIFFS SYSTEM